Zxt‐120 information – Remotec ZXT-120 V1.1 User Manual
Page 9

9
ZXT‐120 Information
How to get the NIF “Node Information Frame” on ZXT‐120  (Inclusion) 
 
Step
Setup Key
LED Indication Status
on ZXT‐120
1
Press the PROG button on the 
ZXT‐120 
• LED flashes once
then stay off
(ZXT‐120 will report 
the supported 
command class) 
Parameter No. and Parameter Value of configuration command 
 
Parameter
Number
Definitions
Parameter Value
25
(0x19)
Indicate a location for IR code 
learning and start learning 
0‐22 
(0x00 – 0x16) 
26
(0x1A)
Learning status register 
 
 
 
Note:  
The status value 0x01 and  
0x04 will be reset to 0 when 
the ZXT‐120 receive a get 
command to this parameter 
0x00: Idle ‐ this IR 
channel is idle 
(default) 
 
0x01: OK ‐ the latest 
learning process 
successful and 
completed 
 
0x02: Learning ‐ the 
ZXT‐120 is busy 
processing previous 
learning request 
 
0x04: Failed ‐ the 
latest learning 
request failed 
27
(0x1B)
IR code number for built‐in 
code library  
Refer “Code list” for 
details 
28
(0x1C)
External IR Emitter power 
level 
 
0x00: normal power 
mode 
0xFF: high power 
mode (default) 
32
(0x20)
Surround IR control
-
to avoid the IR interference 
by disabling the 
surrounding IR emitter if 2 
0x00: disable 
Surround IR Emitters 
0xFF: enable 
Surround IR Emitters 