Connect the remote control with room sensor to the heat pump manager or to the
heat pump with a phone cable. You need 3 wires. For this, use connection terminals
X3.17 and X3.18 and X3-ground on heat pump types CMF/CMT 120 and CMF/
CMT 160 in accordance with the connection plan (figure: heat pump connection plan
drawn in truncated form)
Electrical connection
Terminal block X3
connection layout CMF/CMT 120/160
Cir
culation pump HK 2
Mixer cir
cuit
Switching valve
Hot-water usage
Switching valve, cooling
Cir
culation pump, cooling
Char
ging pump, indoor
module
Cir
culation pump, solar
or cir
culation or Solid-fuel
combustion vessel
F 17 Return, heat pump
F 14 Solar collector
F 12 Refer
ence sensor
, lower buf
fer storage
F 11 Inlet, heat pump
F 9 Outdoor temperatur
e
F 8 T
-collector (com. inlet)
F 6 W
arm-water storage
F 5 Inlet HK2 (mixing cir
cuit
Analogue r
emote contr
ol with r
oom sensor FBR-2
F 15 Flow rate transmitter
Refer
ence sensor
, Solid fuel boiler
, Storage
tank bottom F1