Operation

Two rotary knobs are located on the
front side of the remote control with
room sensor. The left-hand rotary knob
is a switch that can be used to set the
mode. The following modes can be
selected:

1 Automatic mode (operates according

to time programme 1 in controller)

2 Automatic mode (operates according

to time programme 2 in controller)

24 hour night programme

(Decreasing temperature)

24 hour daytime programme

(Comfort temperature)

Summer mode (Heating OFF, only

hot water)

Rotary knob for
adjusting the
nominal room tem-
perature

Rotary knob for
mode selection

The mode on the heat pump manager

must be set to "Automatic 1".

NOTE

The right-hand rotary knob can be used
to set the nominal room temperature.
The adjustment range is ± 5K from the
programmed room temperature on the
heat pump manager. There is a tolerance
of ± 2K.

Nominal room temperature according to

programming on heat pump manager

Nominal room temperature around

5 K warmer than programming on

heat pump manager

Nominal room temperature around

5 K warmer than programming on

Heat pump manager