REMKO RKV 10 W User Manual
Page 7
![background image](https://www.manualsdir.com/files/802030/content/doc007.png)
7
HEAT mode
The HEAT mode is not active for these units.
HEAT
AUTO mode
After pressing the AUTO HEAT button, AUTO appears on the display. The desired
room temperature is kept constant. If the set temperature is exceeded by 2 °C , cool-
ing mode is activated. The operation is the same as it is in the COOL mode. We also
recommend setting the fan to FAN AUTO.
AUTO HEAT
SWING
AUTO
°c
FAN AUTO
22.0
AUTO HEAT
COOLING
Functional process
15.5
AUTO
25.0
AUTO
TEMP.
Sleep button
SLEEP
SLEEP
SLEEP
°c
/ any button
Functional process
By pressing the SLEEP button, the room temperature increases by 1 °C one hour af-
ter the function has been activated. This function can be cancelled by pressing any
button. The
SLP
sign disappears and the normal display appears.
25.0
SWING
AUTO
FAN AUTO
SLP
SLP
Use the COOL mode when you want to cool the room to the desired temperature.
Reduce the desired temperature by pressing the Temperature button in 0.5 °C incre-
ments. After you hear a beep, the COMP. display begins to blink for approximately
3 minutes. This waiting period is a forced pause to increase the service life of the
compressor and the outdoor part. Once the display stops blinking, the air-conditioner
begins working. If the temperature in the room falls 1 C° below the set temperature,
the regulator switches cooling off.
COOL mode
COOL
TEMP.
COOL
25.0
COOLING
COOL
Functional process
SWING
COOL
°c
FAN
25.0
15.5
COOL
Functional process
The COOL / DRY mode dehumidifies the room in an unregulated fashion. The tem-
perature of the plate fin exchanger of the indoor unit almost always falls below the
dew point of the air which causes the moisture in the air to condense on the plate fins.
The dehumidification capacity is based on the moisture in the air and the room tem-
perature. After the DRY button has been pressed, the desired temperature can be se-
lected and the unit begins working. The fan switches off at specific intervals to lower
the plate fin temperature. You can exit this mode by switching to a different one.
COOL/DRY mode
DRY
SWING
COOL / DRY
°c
FAN AUTO
25.0
DRY
DEHUMIDIFICATION
25.0
COOL
15.5
COOL
TEMP.