Remko rks, Technical data – REMKO RKS 435 H User Manual
Page 17
Technical data
1
REMKO RKS
Series
RKS 435H
RKS 448H
�un�tion��
Outdoor unit for �ooling and heating
Rated refrigerating �apa�ity 1)
ing �apa�ity 1)
kW
3,49
4,78
Rated heating �apa�ity 2)
kW
3,78
5,17
Outdoor unit operating range - �ooling
°C
+21 to +45 (with optional winter �ontroller -10 to +45)
Outdoor unit operating range - heating
°C
-7 to +21
Refrigerant
R 410A
Max.� operating pre����ure, per refrigerating �ir�uit
kPa
3800 / 1200
Max.� volumetri� air flow
m³/h
2000
2100
Max.� noi��e level 3)
dB(A)
49
51
Power ��upply
V/Hz
230 / 1~/ 50
Degree of prote�tion
�P
24
Rated ele�.� power �on��umption – �ooling 1)
kW
1,07
1,48
Rated ele�.� �urrent �on��umption – �ooling 1)
A
4,91
6,91
Rated ele�.� power �on��umption – heating 2)
ing 2)
kW
1,09
1,51
Rated ele�.� �urrent �on��umption – heating 2)
heating 2)
A
4,99
7,01
Max.� ele�.� ��tarting �urrent
A
24
32
Ba��i� refrigerant quantity
kg
1,35
1,56
Additional refrigerant quantity > 5m
g/m
22
�nje�tion pipe refrigerant �onne�tion
�n�h (mm)
1/4 (6,35)
Su�tion pipe refrigerant �onne�tion
�n�h (mm)
1/2 (12,7)
Max.� refrigerant pipe length
m
15,0
Max.� refrigerant pipe height
m
8,0
Dimen��ion�� Height
mm
540
Width
770
Depth
290
Weight
kg
37,0
41,0
Serial number
657.�.�.�
658.�.�.�
�T no.�
1619200
1619210
1) External temperature TK 35°C / �K 24°C, �ombined with RXW 350 / RXW 480
2) External temperature TK 7°C / �K 6°C, �ombined with RXW 350 / RXW 480
3) Clearan�e 1 m