INSTALLATION AND CLEARANCES
FOR VENT-FREE OPERATION

WARNING: Maintain the mini-

mum clearances. If you can, pro-

vide greater clearances from floor,

ceiling and adjoining wall.

INSTALLATION

Continued

LOG SIZING REQUIREMENTS

Minimum Firebox

Height

Depth

Front

Rear *

Width

Width

17"

14"

28"

21"

* Measured at 14" depth.

MINIMUM FIREPLACE CLEARANCE TO

COMBUSTIBLE MATERIALS

Side Wall

Ceiling

16"

42"

Carefully follow the instructions below. This will

ensure safe installation into a masonry, UL127-listed

manufactured fireplace or listed vent-free firebox.
Minimum Clearances For Side Combustible
Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 4.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace cabinet (see Figure 4).

Note:

When installing your gas logs into

a manufactured firebox, follow firebox

manufacturerʼs instructions for minimum

clearances to combustible materials.

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

Example

NOTICE: Manual control heaters

may be used as a vented product.

If so, you must always run heater

with chimney flue damper open.

If running heater with damper

open, noncombustible material

above fireplace opening is not

needed. Go to Installing Damper

Clamp Accessory for Vented

Operation, page 11.

MINIMUM NONCOMBUSTIBLE
MATERIAL CLEARANCES
If Not Using Mantel
Note:

If using a mantel proceed to If Using Mantel.

If not using a mantel, follow the information on

this page.
You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2 inch thick. With sheet metal, you must have

noncombustible material behind it. Noncombustible

material must extend at least 8" up (for all models).

If noncombustible material is less than 12", you

must install the fireplace hood accessory. See Figure

5, page 10, for minimum clearances.
If Using Mantel
You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2 inch thick. With sheet metal, you must have

noncombustible material behind it. Noncombus-

tible material must extend at least 8 inches up).

If noncombustible material is less than 12", you

must install the fireplace hood accessory. Even if

noncombustible material is more than 12", you may

need the hood accessory to deflect heat away from

your mantel shelf. See Figures 5, 6 and 7, page 10,

for minimum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chimney

flue damper open. Go to Installing Damper Clamp

Accessory for Vented Operation, page 11.

*