PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 15,

page 14).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Make sure control knob of heater is in the OFF

position.

4. Check all joints from equipment shutoff valve

to control valve (see Figures 16 and 17). Apply

noncorrosive leak detection fluid to all joints.

Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 16)

depending on your model). Check all other

internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Ap-

pliance, page 18 or 20, depending on your

model).

INSTALLATION

Continued

Figure 16 - Checking Gas Joints

(Propane/LP only)

Gas Control
Valve Location

Propane/LP
Supply Tank

Equipment
Shutoff Valve

Figure 17 - Checking Gas Joints (Natural

Gas Only)

Gas Meter

Gas Control
Valve Location

Equipment
Shutoff Valve

Figure 18 - Rear Log Placement (Variable

Manually-Controlled Models)

Rear Log

INSTALLING LOGS

WARNING: Failure to position

the parts in accordance with these

diagrams or failure to use only

parts specifically approved with

this heater may result in property

damage or personal injury.

CAUTION: After installation

and periodically thereafter,

check to ensure that no flame

comes in contact with any log.

With the heater set to HI, check

to see if flames contact any log. If

so, reposition logs according to

the log installation instructions

in this manual. Flames contact-

ing logs will create soot.

It is very important to install the logs exactly as

instructed. Do not modify logs. Only use logs

supplied with heater.
Variable Manually-Controlled Models
(LSL)
1. Place rear log onto rear brackets making sure

brackets fit into recess on bottom of log (see

Figure 18).

2. Place left front log on grate fingers as shown

in Figure 19, page 16. Place right front log on

grate fingers and on left front log (see Figure

19, page 16).

3. Slide control cover log into position between

two front logs assuring the cover log seats into

cutout section (see Figure 20, page 16).