beautypg.com

Operating heater – Desa CDL3924PT User Manual

Page 17

background image

www.desatech.com

111347-01E

17

LIGHTING

INSTRUCTIONS

WARNING:

• If fireplace has glass doors,

never operate this heater with

glass doors closed. If you op-

erate heater with doors closed,

heat buildup inside fireplace

will cause glass to burst. Make

sure there are no obstructions

across opening of fireplace.

• You must operate this heater

with a fireplace screen in place.

Make sure fireplace screen is

closed before running heater.

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Orange flame will also be pres-

ent. Open damper or window to

vent smell. This will only last a

few hours.

Note:

Home owners generally prefer to operate

their heater with the chimney damper closed.

This will put all the heat into the room. How-

ever, there may be times you will desire the full

flames of the HI heat setting but will find the

heat output excessive. You can open the chim-

ney damper (if you have one) fully or partially

to release some of the heat.

WARNING: Damper handle will

be hot if heater has been running.

1. STOP! Read the safety information on

page 16.

2. Remove control cover log (see Figure 23).

3. Make sure equipment shutoff valve is fully

open.

4. Press in and turn control knob clockwise

to the OFF position.

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information, page 16. If you donʼt

smell gas, go to the next step.

6. Slightly depress and turn control knob

counterclockwise

to the PILOT

position. Keep control knob pressed in for

five (5) seconds (see Figure 23).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

7. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the burner. If needed,

keep pressing ignitor button until pilot

lights. Note: If pilot does not light, contact

a qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 18.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service

person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3

through 7.

9. Slightly depress and turn control knob

counterclockwise

to the HI position.

The burner should light. Set control knob

to any heat level between HI and LO.

10. Replace control cover log (see Figure 23).

OPERATING HEATER

Continued

Figure 23 - Control Knob and Ignitor

Button Location (Actual Logs May Vary)

Control
Knob

Ignitor
Button

Control
Cover
Log

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 24 - Pilot

(Note: Appearance of pilot assembly may vary

by model.)

This manual is related to the following products: