CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

CAUTION: Never connect pro-

pane/LP fireplace directly to the

propane/LP supply. This heater

requires an external regulator

(not supplied). Install the exter-

nal regulator between the heater

and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This

gas is commonly known as

wellhead gas.

Installation Items Needed
Before installing heater, make sure you have the

items listed below.
• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench
* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from

your dealer. See Accessories, page 27.
For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

INSTALLATION

Continued

as shown in Figure 13. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new, black

iron or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter or

greater to allow proper gas volume

to heater. If pipe is too small, undue

loss of volume will occur.

Installation must include an equipment shutoff valve,

union and plugged 1/8" NPT tap. Locate NPT tap

within reach for test gauge hook up. NPT tap must be

upstream from heater (see Figure 14, page 14).
IMPORTANT:

Install equipment shutoff valve in an

accessible location. The equipment shutoff valve is for

turning on or shutting off the gas to the appliance.
Check your building codes for any special

requirements for locating equipment shutoff

valve to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figures 14, page 14. Locate

sediment trap where it is within reach for clean-

ing. Install in piping system between fuel supply

and heater. Locate sediment trap where trapped

matter is not likely to freeze. A sediment trap

traps moisture and contaminants. This keeps them

from going into heater controls. If sediment trap

is not installed or is installed wrong, heater may

not run properly.

Propane/LP
Supply Tank

External
Regulator

Figure 13 - External Regulator With Vent

Pointing Down

Vent
Pointing
Down