beautypg.com

Operating heater – Desa CDL3924PT User Manual

Page 19

background image

www.desatech.com

111347-01E

19

LIGHTING

INSTRUCTIONS

WARNING:

• If fireplace has glass doors,

never operate this heater with

glass doors closed. If you op-

erate heater with doors closed,

heat buildup inside fireplace

will cause glass to burst. Make

sure there are no obstructions

across opening of fireplace.

• You must operate this heater

with a fireplace screen in place.

Make sure fireplace screen is

closed before running heater.

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Orange flame will also be pres-

ent. Open damper or window to

vent smell. This will only last a

few hours.

Note:

Home owners generally prefer to op-

erate their heater with the chimney damper

closed. This will put all the heat into the room.

However, there may be times you will desire

the full flames of the HI heat setting but will

find the heat output excessive. You can open

the chimney damper (if you have one) fully or

partially to release some of the heat.

WARNING: Damper handle

will be hot if heater has been

running.

1. STOP! Read the safety information in

column 2, page 18.

2. Make sure equipment shutoff valve is

fully open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information in column 2, page 18. If

you donʼt smell gas, go to the next step.

OPERATING HEATER

Continued

5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 25).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

• If control knob does not pop out when

released, contact a qualified service

person or gas supplier for repairs.

6. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the front burner. If

needed, keep pressing ignitor button until

pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 20.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one (1) minute for system to

reset before lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The burners should

light. Set control knob to any heat level

between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

LO

HI

OFF

Pilot

Figure 25 - Control Knob and Ignitor

Button Location

Control Knob

Ignitor
Button

Figure 26 - Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

This manual is related to the following products: