Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

Noncombus-
tible Material
Distance (A)
12" or more

Between 8" and
12"

Less than 8"

Requirements for Safe
Installation

Noncombustible Mate-
rial OK.
Install fireplace hood
accessory (GA6050,
GA6052 or GA6053 see
Accessories, page 27)
Noncombustible materi-
als must be extended to
at least 8". See Between
8" and 12"
above. If you
cannot extend material,
you must operate heater
with flue damper open.

INSTALLATION

Continued

Minimum

Noncombustible

Material

Minimum Non-

Combustible

Material Height

Distances to

Underside of

Mantel

Top of

Fireplace

Opening

Underside of

Mantel Shelf

Mantel Shelf

12"
8"

(A)

18"
8"

20"
14"

22"
17"

24"
20"

All minimum

distances are

in inches

Log Set
24"/30"/36"

Models
18" Model

2

1/2

"

6"

8"

10"

MANTEL CLEARANCES

In addition to meeting noncombustible material

clearances, you must also meet required clearances

between fireplace opening and mantel shelf. If

you do not meet the clearances listed below, you

will need a hood.
Determining Minimum Mantel Clearance
If you meet minimum clearance between mantel

shelf and top of fireplace opening, a hood is not

required (see Figure 6).
Determining Minimum Mantel Clearance
When Using a Hood
If minimum clearances in Figure 6 are not met, you

must have a hood. When using a hood there are

still certain minimum mantel clearances required.

Follow minimum clearances shown in Figure 7

when using hood.

Figure 6 - Minimum Mantel Clearances

Without Using Hood

Figure 7 - Minimum Mantel Clearances

When Using Hood

Minimum

Noncombustible

Material

8"

Min.

12" 15"

18"

All minimum

distances are

in inches

20"

2

1/2

"

6"

8"

10"

12"

Distances to

Underside of

Mantel

Hood

(GA6050,

GA6052 or

GA6053)

Top of

Fireplace

Opening

Underside

of Mantel

Shelf

Mantel Shelf

Hood
(GA6050,
GA6052 or
GA6053)

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.