Remko rvs...h (inox) – REMKO RVS 60 H User Manual
Page 8
Icon General alarm
The icon, displays the respective
code, and fault.
Icon Defrosting status
The icon(lights up) displays
that the defrosting cycle in the
fin condenser is active. When
blinking the controller is calcu-
lating the necessary defrosting
time.
Icon Frost protection heating
The LED provides information
about the operating status for
the frost protection heating
medium.
Icon "Fault"
The LED shows that there is a
fault.
Icon Compressor 1
The illuminated LED indicates
that compressor 1 is in ope-
ration. The LED blinks if the
compressor is in safety mode.
Icon Compressor 2
See description point .
Icon Compressor 3
See description point .
Icon Compressor 4
See description point .
Value display
The value display shows current
values.
Operating the controller µC
2
SE
The controller has 3 modes:
1. Summer mode (cooling mode)
In cooling mode, the warmer me-
dium temperature is cooled to the
preset cooler temperature.
2. Transition mode (heating mode)
In heating mode, the cooler me-
dium temperature is heated to the
preset warmer value.
3. Standby mode (Stand-by)
In the Stand-By mode, safety
equipment is active but no operat-
ing mode is set.
Key-Pad " "
Using this key-pad, the current-
menu can be exited.
Key-Pad " "
This key-pad is used for se-
lecting open/close, a selected
value or parameter.
Key-Pad " "
Prolonged pressing (5 sec.)
allows switching between the-
operating modes „Cooling“and
„Stand-By“.Short pressing,
displaysof the current values
for the temperature probes B1
to B3 and the pressure trance-
ducer B4. A value can also be
increased.
Key-Pad " "
Prolonged pressing (5 sec.)
allows switching between the-
operating modes „Heating“and
„Stand-By“. Short pressing
displaysthe current values for
the temperature probes B1 to
B3 and the pressure trance-
ducer B4. A value can also be
reduced.
Key-Pad " and " together
Pressing long (5 sec.)and
together and on entering a
password, the parameter level is
opened.
Key-Pad " and " together
Pressing long (5 sec.) and
together allows the acknow-
ledgement of a pending faults
or operating hours.
Key-Pad " and " together
in heating mode
Longer pressing together
triggers manual defrosting in
heating mode.
Icon cooling mode
The icon displays the selected
cooling mode.
Icon heating mode
The icon displays the selected
heating mode.
Icon "Fan"
The icon lights up, if the con-
denser fan is activated.
Icon "Pump"
The icon lights up, if the circula-
ting pump is activated.
+
+
+
Controller control panel µC
2
SE
During the initialization of the
controller (after starting the
unit and displaying the soft-
ware version, e.g. “H 99”) do
not push the key-pad “Prg”
to avoid reprogramming the
controller!
!
CAUTION
REMKO RVS...H (INOX)
8