2 technical data, 1 unit data, Technical data 2.1 unit data – REMKO RKL 300 User Manual
Page 7: 2technical data
2
Technical data
2.1 Unit data
Series
RKL 300
RKL 300
RKL 360
RKL 360
Operating mode
Local compact air conditioning unit for cooling
Nominal cooling output
1)
kW
3.2
3.6
Energy efficiency ratio - cooling
A
A
Energy efficiency rating EER
1)
2.8
2.7
Energy consumption, hourly
kWh/60 min
1.13
1.33
Approx. application area (room volume)
m³
90
100
Adjustment range indoor unit
°C
+18 - +30
+18 - +30
Operating range - indoor unit
°C / %r.F.
+18 - +35 / +35 - +85
+18 - +35 / +35 - +85
Refrigerant
R 410A
3)
R 410A
3)
Refrigerant, basic capacity
kg
0.73
0.73
Max. operating pressure / cooling cycle
kPa
1160 / 4120
1160 / 4120
Air flow volume per stage
m³/h
360 / 410 / 450
360 / 410 / 450
Sound pressure level per stage
2)
dB(A)
49 / 51 / 53
49 / 51 / 53
Sound power level max.
dB(A)
61
61
Power supply
V/Ph/Hz
230 / 1~/ 50
230 / 1~/ 50
Enclosure class
IP
20
20
Electr. rated power consumption
1)
kW
1.13
1.33
Electr. rated power consumption
1)
Standby operation
0,4
0.4
Electr. rated current consumption
1)
A
5.0
5.9
Elec. starting current max., LRA
A
21
25
Exhaust air hose, length / diameter
mm
1500 / 130
1500 / 130
Max. condensate pump pressure
l/h
6.0
6.0
Dimensions - height
mm
840
840
Dimensions - width
mm
450
450
Dimensions - depth
mm
380
380
Weight
kg
35.0
35.0
Standard colour
white
silver
white
silver
Serial number
1250...
1251...
1252...
1253...
EDP no.
1615300
1615301
1615360
1615361
1)
Room air temperature TK 35 °C, FK 24 °C /
2)
Distance 1m free field
3)
Contains greenhouse gas according to Kyoto protocol
7