10 shutdown, Shutdown – REMKO RKL 300 User Manual
Page 19
Fig. 17: Cleaning with lukewarm water
10
Shutdown
NOTICE!
Never switch off the equipment by pulling out
the mains plug.
Temporary shutdown
If it is planned to shut down the unit for longer
periods e.g. during the winter, proceed as follows:
1.
Let the unit run in recirculating operation for
ca. 2 hours in order to dry the surfaces of the
evaporator fins. This will transport the
remaining moisture out of the unit and this
will avoid unpleasant odours when the unit is
re-commissioned.
2.
Switch the unit off with the "I/O" key, pull out
the power plug and wind up the power
supply. Ensure that the wiring is not kinked or
too severely bent. The line can be fastened
to the rear of the unit.
3.
Place a suitable container underneath the
condensate drain of the internal reservoir.
The condensate drain is located on the lower
rear side of the unit.
4.
Pull out the stopper from the condensate
drain and collect the condensate that drains
out.
5.
Then insert the stopper once again. A
missing stopper or an incorrectly inserted
stopper will result in condensate leaking out
after re-commissioning.
6.
Store the unit in an upright position in a cool,
dry and dust-free location protected from
direct sunlight. Cover the unit with a synthetic
cover to protect it against dust if desired.
Permanent shutdown
The entire system should only be dismantled by a
specialist firm familiar with all environmental
aspects involved. REMKO GmbH & Co. KG or your
sales partner will be pleased to provide details of
refrigerant specialists in your area.