Remko rkl – REMKO RKL 300 User Manual
Page 10
7
"COMP. ON" key
Cooling capacity will now only be generated whilst
the compressor is active. Upon reaching the pro-
grammed target temperature, the compressor and
thus the cooling capacity will be switched off. The
recirculating fan however, continues to run. During
compressor operation the
7
LED illuminates.
8
Cooling mode: "AUTO, HI, MED, LO" LED
See
2
.
NOTICE!
You will achieve a pleasant room temperature
if you set the desired target temperature max.
4 to 7 °C below the outside temperature.
9
Circulated air operation: "FAN" LED
In this operating mode the air in the room is recir-
culated in the unchangeable medium stage. The
unit does not cool the air.
10
"TIMING ON" LED
The switch on timer is active.
11
"TIMING OFF" LED
The switch off timer is active.
12
"DRAIN WATER" display
The condensate arising will be collected in an
internal reservoir, fed to the condenser and evapo-
rated there. The evaporated condensate will then
be fed to the outside via the exhaust air hose. If
the condensate cannot be fed away then a fault
shut-down is initiated along with an LED
12
signal-
ling this. In order to be able to use the unit again
after this fault shut-down, proceed as follows:
1. Switch the unit off with the "I/0" key and pull out
the power plug.
2. Place a suitable container underneath the con-
densate drain of the internal reservoir. The con-
densate drain is located on the lower centre on the
rear of the unit.
3. Pull out the stopper from the condensate drain
and collect the condensate that drains out.
4. Then insert the stopper once again.
13
Display
The programmed room temperature or the
remaining time for the timer is shown on the dis-
play.
14
"REMOTE" IR receiver
The IR remote control should be pointed at this
receiver sensor in order to guarantee the opera-
tion.
Infrared remote control
General Information
n
With the unit switched on any change to the
settings will be automatically transferred to the
room air conditioner. The proper receipt of data
will be acknowledged with an audible "beep".
n
To operate the remote control should be
pointed towards the receiver. The receipt of
data is only possible if there are no objects
between the transmitter and the receiver.
n
If the system is shut down for an extended
period it is advisable to remove the batteries
from the remote control.
NOTICE!
Never use new and used batteries at the same
time, remove discharged batteries immediately
and replace these with new batteries of the
prescribed quality as there is a danger of dis-
charged batteries leaking.
REMKO RKL