View alarms, Display all alarms, Display active alarms – Quintum Technologies Tenor Call Relay 60 User Manual
Page 50: View alarms -6, Display all alarms -6, Display active alarms -6

P/N 480-0076-00-00
5-6
Chapter 5: System Alarms
View Alarms
The Command Line Interface (CLI) enables you to view alarms through the Monitor mode. You can
view active alarms, as well as view an alarm history list.
Display all Alarms
You are able to display both active alarms and an alarm history as follows:
1. Through CLI, access the Monitor prompt.
2. Type alarm. Both active alarms and the alarm history will be displayed. See section
for field definitions.
Figure 5-1 Alarm sample
IP# Sequence# Type Severity Desc Slot# Device# Line# Channel# Date/Time
192.168.20.444:4:ALR:1:Call Handler not Registered with Gatekeeper:0:0:0:0:THU JAN 13 13:21:27 2005
192.168.20.444:5:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) register):0:0:0:0:THU JAN 13 13:21:27
2005
Display Active Alarms
1. Through CLI, access the Monitor prompt.
2. Type alarm a. The active alarms will be listed. See section
for field defini-
tions. If you enter alarm without a command following it, both active alarms and the alarm his-
tory will be displayed.
Figure 5-2
IP# Sequence# Type Severity Desc Slot# Device# Line# Channel# Date/Time
192.168.20.444:10:CLR:3:Border Element connection lost:0:0:0:0:THU JAN 13 13:21:27 2005
Active Alarm Sample