Proel PC260 User Manual
Page 17
17
FIRMWARE UPDATE
This page is where the PC260 Firmware can be updated from USB port . To
update the firmware a PC with PRONET software installed is required . Both the
firmware and the PRONET software can be downloaded from proel web site
(www .proel .com) . In the PRONET documentation you can find the instruction
to update the firmware . Press ESC or PG UP/DW buttons to escape from this
page, press SETUP to proceed with the firmware update, the following screen
appears on the display:
Now the PC260 still waiting the PRONET program to send the firmware thru USB
port, if you want to escape from this procedure without update the firmware you
have only a solution: TURN OFF and TURN ON again the PC260 .
LOCK
This page is where the PC260 can be locked or unlocked by the installer/operator . There are four LOCK levels available, indicated by
a padlock in the first line of the display:
FULL EDIT
PARTIAL LOCK
PRESET LOCK
TOTAL LOCK
For setting a different LOCK level, rotate the DATA knob to select the level, press the DATA knob to confirm the new level and then
input a password using again the DATA knob . Press SETUP again for confirming all data .
Press ESC or PG UP/DW buttons to escape from this page without changing the lock status .
FULL EDIT
This is the defult LOCK level when you turn on the PC260 for the first time
or when an operator performs a FULL SYSTEM RESET . All routing setting
sare available and all DSP input and output parameters are accessible and
adjustable (only input parameters for Factory and protected presets) . Resulting
settings can be saved into any User Preset location for later recall . Editing can
be performed from the control panel or from a PC with PRONET software .
PRESET LOCK
This LOCK level allows only the USER Presets saved in the processor's memory
to be recalled . The only other parameter accessible is the inout and output
MUTE
This LOCK mode level can be used by installators who want to save a number
of different presets for the sound system and then lock any other parameter
except the preset recalling .
PARTIAL LOCK
Limited editing can be performed on Factory, Protected and User presets:
- INPUT parameters: DELAY, GEQ, PEQ, DEQ, DYN, mute and level;
- OUTPUT parameters: mute and TRIM level;
- SPL Management .
TOTAL LOCK
NO editing can be performed on the processor, including the preset recall .
Note: when the SPLM is activated the PC260 is forced in the TOTAL LOCK status .