Power on/off – Posiflex DT-308 User Manual
Page 12

Part 12
disabled or when pop up warning message like this picture appears, please
replace the used up UPS battery at power off as soon as possible.
Emergency treatment:
The battery is constructed maintenance free and leakproof. Its storage space in
DT system also provides very good protection as long as the ambient
temperature remains below 30°C and the ventilation of the DT system remains
free. However, should any accident happen and the sulfuric acid from the
battery spills on skin or clothing, wash immediately with water. If the acid
comes in contact with eyes, rinse eyes with large amount of clean water and
see a doctor immediately. A larger external battery may be connected to give
an extended operation. Please check your dealer about this capability when
required.
WARNING:
If there are any signs of over charging or leakage of electrolyte
please contact your dealer immediately
POWER ON/OFF
Touch Open Front Door
A gentle tap on the touch open front door at
front side of the main unit will open the cover
and show the power switch and a USB port. It
is preferable to keep this door closed through
daily operation. There must always be at least 10 seconds waiting before
switching on again once the system is powered off successfully.
Power Indicator
The power status of the system is indicated by the LED to the right of the front
door. The relationship between the indicator status and other conditions is
summarized in following table:
Indicator Status
System
Status
External
Power
UPS Battery Powering Up
Off
Off
Off
Not present
Not possible
Off
Off
Off
Present
Not allowed
Yellow
Off
On
No influence
Allowed
Blue
On
On
No influence Not required
Blue/flash
On
Off
Activated
Not required
Yellow/rapid flash
On
Off
Running at
low capacity
Not required