beautypg.com

Paloma MIC-180 User Manual

Page 10

background image

6. Typical Installation of Extended Manifold Controller For Manifolding seven
(7) to twenty (20) Water Heaters

Manifold controller (MIC-180) provides control of two (2) to six (6) water heaters when properly
installed and connected with communication cables (sold separately) to any Rheem-Ruud or Paloma
commercial Tankless Water Heaters. To control additional water heaters (7 to 20 water heaters), it is
necessary to purchase separately and install an extended communication PCB (MICS-180) in the
control system.

Example of typical installation using both main communication PCB and extended communication
PCB (MICS-180) is shown below in figure 12.

































Manifold box

Communication cable

from water heater No. 1

Ground wire

Power wires

Main communication PCB (For

manifolding 2 to 6 heaters)

Junction box

Figure 12

LED Display (Displays error code

and selected water heater)

Relay cable

Communication cable

from water heater No. 7

Wiring from main

remote control

Extended communication PCB (For

manifolding 7 to 20 heaters)








-

10

-