RAID MANAGEMENT

The G4 GraniteRack can implement several different levels of RAID technology. These RAID levels are
supported by the system:

RAID Level

Description

Minimum Number of Drives

0

Block striping is provided, which yields higher
performance than with individual drives. No
redundancy.

1

1

Drives are paired and mirrored. All data is
duplicated on an equivalent drive. Fully
redundant.

2

3

Data is striped across several physical drives.
Parity protection is used for data redundancy.

3

5

Data is striped across several physical drives.
Parity protection is used for data redundancy

3

6

Data is striped across several physical drives.
Parity protection is used for data redundancy.
Requires N+2 drives to implement because of
two-dimensional parity scheme.

4

0 + 1

Combinations of RAID levels 0 and 1. This level
provides striping and redundancy through
mirroring.

4