9.13 Set environment alarm limits

Set environment alarm limits

::= 'env' 'b' 'm' 'nom'|'ul'|'ll'
['temp=']
['voltage1='['mV'|'V']]['voltage2='['mV'|'V']]
['voltage3='['mV'|'V']]['voltage4='['mV'|'V']]
['fan1='['rpm']]['fan2='['rpm']]
['timer1=']['timer1=']

::= [ {}]

::= 'env' 'b' 'm' 'nom'|'ul'|'ll'
['temp=']
['voltage1=']['voltage2=']
['voltage3=']['voltage4=']
['fan1=']['fan2=']
['timer1'=]['timer1=']

Where:

nom

List nominal values

ul

List upper limit

ll

List lower limit


env b1 m0 nom voltage1=1700mV

? "env b1 m0 nom voltage1=1700mV"

env b1 m0 nom voltage1=1700mV voltage2=3300mV voltage3=5000mV
voltage4=12000mV

9.14 List environment status

List the environment status.

::= 'senv' ['stat'|'nom'|'ul'|'ll']

::= [ {}]

senv

? "senv"

env b1 m0 temp=38.00 voltage1=1794mV voltage2=3222mV
voltage3=5002mV voltage4=11860mV fan1=5758rpm fan2=5756rpm
timer1=8864 timer2=8864

env b1 m1 temp=33.75 voltage1=1791mV voltage2=3193mV
voltage3=5024mV voltage4=12014mV fan1=3243rpm fan2=3239rpm
timer1=24657 timer2=24657