7 input signal presence status – Nevion Multicon MRP User Manual
Page 27

Modular Routing Protocol - MRP
Rev. L
nevion.com | 27
6.7 Input signal presence status
This command and status applies to levels, virtual tables and salvos.
Input signal presence messages are also sent as status messages when the status
changes.
following values:
p
Present. All signals are reported as present.
m Missing. One or more inputs do not have a valid signal
u
Unknown. One or more inputs are not able to report if a signal is
present or not.
Examples:
Command:
Response:
Command:
Response:
sspi l16
? "sspi l16"
sspi l16 0 p
sspi l16 1 m
sspi l16 2 m
sspi l16 3 m
sspi l16 4 p
sspi l16 5 p
sspi l16 6 p
sspi l16 7 p
sspi sg1
? "sspi sg1"
sspi sg1 1 p
sspi sg1 2 u
sspi sg1 3 m
sspi sg1 4 u
sspi sg1 5 u
sspi vt4
? "sspi vt4"
sspi vt4 0 p
sspi vt4 1 vl1 m vl2
u
sspi vt4 2 m
sspi vt4 3 u
sspi vt4 4 p
sspi vt4 5 u
sspi vt4 6 vl1 p vl2
m
sspi vt4 7 vl1 p vl2
u