6.7 Input signal presence status

This command and status applies to levels, virtual tables and salvos.

Input signal presence messages are also sent as status messages when the status
changes.

::= 'sspi'

::= [ {}]

::= 'sspi' ||

::= 'l'

::= 'vt' |('vl'
)+

::= 'sg'

::= 'p'|'u'|'m'

Current status for the input, source or salvo, can be one of the

following values:

p

Present. All signals are reported as present.

m Missing. One or more inputs do not have a valid signal

u

Unknown. One or more inputs are not able to report if a signal is
present or not.

Examples:

Command:

Response:

Command:

Response:


sspi l16


? "sspi l16"
sspi l16 0 p
sspi l16 1 m
sspi l16 2 m
sspi l16 3 m
sspi l16 4 p
sspi l16 5 p
sspi l16 6 p
sspi l16 7 p

sspi sg1


? "sspi sg1"
sspi sg1 1 p
sspi sg1 2 u
sspi sg1 3 m
sspi sg1 4 u
sspi sg1 5 u


sspi vt4


? "sspi vt4"
sspi vt4 0 p
sspi vt4 1 vl1 m vl2
u
sspi vt4 2 m
sspi vt4 3 u
sspi vt4 4 p
sspi vt4 5 u
sspi vt4 6 vl1 p vl2
m
sspi vt4 7 vl1 p vl2
u