OPERATION (cont.)

Condensate Pump Kit (Optional)

A condensate pump kits are available to allow continuous operation and to

eliminate the need for a drain tank.

When the water collects to level (A) in the

pump reservoir, the condensate pump

begins to operate and discharge the

water.

Note: The compressor does not operate

while the condensate pump is discharging the water.

When the water level drops below level (B), the condensate pump stops, and the

compressor restarts.
Note: If for any reason the water level exceeds that of level (A) in the pump

reservoir, an over flow drain switch stops the compressor operation, and the LCD

displays “AS” (see page 25).
Note: If the fan mode control DIP switch (see page 20) is set to the STOP position,

the entire unit (including fan operation) turns off either due to the over flow drain

switch or while the condensate pump is discharging the water.

ILL00064-00

ILL00065-00

MOVINCOOL

O

O

CONDENSATE PUMP

CONDENSATE

PUMP RESERVOIR

DISCHARGE HOSE