Condensate pump kit (optional), Operation (cont.) – MovinCool Office Pro W20 User Manual
Page 27
27
OPERATION (cont.)
Condensate Pump Kit (Optional)
A condensate pump kits are available to allow continuous operation and to
eliminate the need for a drain tank.
When the water collects to level (A) in the
pump reservoir, the condensate pump
begins to operate and discharge the
water.
Note: The compressor does not operate
while the condensate pump is discharging the water.
When the water level drops below level (B), the condensate pump stops, and the
compressor restarts.
Note: If for any reason the water level exceeds that of level (A) in the pump
reservoir, an over flow drain switch stops the compressor operation, and the LCD
displays “AS” (see page 25).
Note: If the fan mode control DIP switch (see page 20) is set to the STOP position,
the entire unit (including fan operation) turns off either due to the over flow drain
switch or while the condensate pump is discharging the water.