beautypg.com

Operating in fan only mode, Changing from fan only mode to cool mode, Keypad lock – MovinCool Classic Plus 14 User Manual

Page 21: Operation (cont.)

background image

21

OPERATION (cont.)

Operating in FAN ONLY Mode

1. The unit can also be operated in FAN ONLY mode by pressing FAN HI/LO

button (LCD indicates “FAN HI/LO” and “COOL OFF”).

2. The unit can only be turned off by pressing the FAN HI/LO button until fan

turns off (FAN ONLY mode speed sequences are High

→ Low → Off.).

Changing from FAN ONLY Mode to COOL Mode

The COOL mode can be activated while the unit is operating in FAN ONLY mode.

To do this, simply press the COOL ON/OFF button

(LCD indicates “COOL ON”).
Note: The FAN ONLY mode does not operate after the COOL mode has been

activated. The unit can only be turned off by pressing the COOL ON/OFF button.

Keypad Lock

Keypad lock disables all buttons on the controller panel except keypad lock and

unlock operations.
1. To lock, press and hold ENTER and SET CLOCK buttons simultaneously for

5 seconds.

2. To unlock, press and hold ENTER and SET CLOCK buttons simultaneously

for 5 seconds again.

Note: When the unit detects operation failure, keypad is unlocked automatically

and self-diagnostic code illuminates.