beautypg.com

Monster HTUPS 3700 User Manual

Page 21

background image

13

e) In the event of a utility power failure, you can still operate your HTUPS

3700, even if the unit was turned off during the

power failure . Only battery backup outlets are still powered by battery during a power failure . Under back-up operation,
the HTUPS

3700 will beep slowly and the LED meter will display how much time is left for battery backup power . In UPS

mode, the unit will beep every five seconds, when there is approximately 25% charge left, it will beep twice every five
seconds . You can turn off the beeping by pressing the Alarm On/Off button once .

f) When the GreenPower switch located on the rear panel is “On,” the GreenPower Control function is enabled and the

alphanumeric LED on the front panel display will show “GRN ON” for 5 seconds . When output power of the GreenPower
Control HDD outlet is over 45w, it will turn on the other 3 GreenPower switched HDD outlets . If the output power of the
master HDD outlet drops down less than 25w, it will turn off the other 3 GreenPower HDD outlets . When the GreenPower
switch is in the “Off” position, the GreenPower Control is disabled and the alphanumeric LED will show ”GRN OFF” for 5
seconds, and all 4 HDD outlets become unswitched outlets .

nOTe: When you push and hold on the Alarm “On/Off” button for 3 seconds, the alphanumeric LED will show “GRN ON
or OFF” for 5 seconds and then return to normal .