beautypg.com

Monster HTUPS 3700 User Manual

Page 20

background image

12

HOOkUP anD OPeRaTIOn InSTRUCTIOnS

nOTe: The HTUPS

3700 must be plugged into a properly grounded, three-prong AC power outlet . In addition,

Monster recommends charging the batteries for at least four hours prior to using HTUPS

3700 . To charge or recharge

the batteries, simply plug your HTUPS

3700 into an AC outlet .

Powering Your HTUPS

3700 and Connected equipment

a) For safety reasons, the HTUPS

3700 ships with the battery disconnected . You must first manually connect the battery .

See p .10 for instructions .

b) Plug your AV equipment you would like to protect from power loss into the surge-protected, battery backup-supplied outlets .

C) Plug the HTUPS

3700 into a properly grounded AC outlet . Always keep the HTUPS

3700 plugged into a live outlet to

ensure the battery is charged .

The HTUPS

3700 will then perform a self-test function . The “Clean Power On” LED will flash 16 times in 8 seconds

and the unswitched outlet will be delayed 8 seconds to output power . The Clean Power On, Protection On,
Unswitched On, UPS/AVR, Ground OK, and Wiring OK LEDs will illuminate steadily . The voltage and wattage meters will
display input AC voltage level, and the battery runtime LED bar will display current battery capacity .

D) Turn on your HTUPS

3700 switched outlets by pressing the Power On button . The Clean Power On, Protection On,

Unswitched On, Ground OK, Switched/Timed On, Wiring OK and UPS/AVR On LEDs will illuminate steadily and the voltage
meter will display input AC voltage level and the battery runtime LED bar will display current battery capacity, confirming
that there is adequate power to the connected loads .