6. Maintenance/Adjustment

6-5

6.2.1 Engine trouble



This unit is equipped with a controller which
memorizes details of engine troubles. When the

engine fails, the diagnosis lamp“1”glows.

Diagnosis lamp lighting pattern indicates the

states of engine failure and it causes engine to

emergency stop.



To solve or repair failures, special knowledge is

required. Contact your nearest distributor or
directly us.

Trouble

Flickering

pattern of

trouble indicator

Functions

Excessive RPM

L 1 and S 1

RPM speed: higher 115% than rated speed

Drop of engine oil

pressure

L 1 and S 2

Functioning oil pressure: less than 0.05MPa

Battery charging faulty

L 1 and S 3

Disconnection of belts stops charging battery.

Rise of coolant

temperature

L 1 and S 4

When engine coolant temperature rises up to 110℃.

Protection of starter

L 1 and S 7

This indicator is “ON” when starter continues to work

longer than 12 seconds.

Malfunction of RPM

sensor

L 2 and S 1

When RPM sensor is in disorder or cable connection is

cut or short-circuited.

Trouble of solenoid

sensor

L 2 and S 2

When cable of actuator is disconnected or

short-circuited.

Disconnection of coolant

temperature sensor

L 2 and S 4

When cable of coolant thermometer is disconnected.

Short-circuiting of

coolant temp. sensor

L 2 and S 5

When cable of coolant thermometer gets

short-circuited.

Disconnection of

alternator L terminal

L 2 and S 6

When cable of alternator L terminal gets

short-circuited.

Trouble of power supply

for sensors

L 2 and S 7

When power cable for ECU gets short-circuited.

Excessive voltage

L 3 and S 1

When voltage of alternator rides abnormally, function

voltage: 18V.

Running out of fuel

L 3 and S 2

When engine stops due to running out of fuel or fuel

system clogging.

Fuses failure

L 4 and S 1

When 5A fuse fails.

※L and S mean long time and short time alternatively. Also the numbers of each L and S mean

repeated time of flickering lamp.

A100407