5. Periodic Inspection/Maintenance

5-4

Maintenance

Daily Every

50 hours

Every

250 hours

Every

500 hours

Every

1,000 hours Page Remarks

Check condensate in the oil fence ○

4-12

Check the terminal portion of

electrical circuits and cable

connections

5-10 Every 4 months

Clean inside of the oil fence and

check it for any rust

5-11 Yearly

Check vibration isolator rubbers

5-13 Yearly

Others

Check each rubber hose

5-13 Yearly

Note:The above intervals of inspection and maintenance are respectively based on the operation time of 125

hours of used per month and of 1,500 hours of use per year.