5. Periodic Inspection/Maintenance

5-6

5.5.2 Change engine oil filter

[At 50 hours for the first change and every 500 hours thereafter]

When installing a new oil filter“1”, spread oil over

the packing“2”, and then screw it in. When the
packing touches the sealing surface, further
tighten the filter by approximately two-thirds turn
with a filter wrench.

After the oil filter“1”is assembled, check if there

are any oil leaks during operation.

(For part number, see 5.3)

5.5.3 Check GFCI receptacles

[Monthly or 250 hours operation, whichever comes first.]



If the generator is stored outdoors, unprotected from the weather, test the GFCI receptacle before
each use.



In case the GFCI has tripped due to the hazard of ground fault currents, investigate the cause and
correct it.

Regularly check the GFCI operation for safety.

Unplug all appliances from the generator.

Start the engine.

Turn each single-phase and three-phase breaker ON.

Press the TEST BUTTON



The RESET BUTTON should extend with a click.



If the RESET BUTTON does not extend, contact your

nearest dealer.

Press the RESET BUTTON

When the RESET BUTTON extends during peration.



Unplug all appliances from the GFCI protected
receptacle.



Press the RESET BUTTON:

IF THE GFCI CANNOT BE RESET: The GFCI is faulty. Contact your nearest dealer.

IF THE GFCI RESETS PROPERLY: Check the appliance or the power cord.

Reset button

Test button

A040270

H000049

1

2