Operation, 4 engine oil ・ coolant ・ fuel – MMD Equipment 40S-8B1 User Manual
Page 29

4. Operation
4-8
4.3.3 The Maximum Combined Simultaneous Power Consumption
Never exceed the maximum combined simultaneous power consumption.
The following chart shows the maximum power available from the 120V-20A GFCI receptacles during
simultaneous consumption (main terminals and receptacles) for both single or three phase settings.
Values shown in the left column give the maximum current available at the 120V-20A GFCI
receptacles compared to the value of the simultaneous current consumption from the main terminals.
SDG40S-8B1 SDG45S-8B2
Single Phase
120V-20A
GFCI Rcept.
Three Phase
240/480V
Single Phase
240/120V
Three Phase
240/480V
Single Phase
240/120V
kW kVA
kVA kVA kVA
0.0 38.0
22.0 45.0 26.0
1.2 33.8
20.8 40.9 24.8
2.4 29.7
19.6 36.7 23.6
3.6 25.5
18.4 32.6 22.4
4.8 21.4
17.2 28.4 21.2
4.4 Engine Oil・Coolant・Fuel
4.4.1 Engine Oil
Viscosity of engine oil greatly affects startability, performance, oil consumption of the engine, as
well as wear of the moving parts.
Choose appropriate oil based upon the table below according to the outside air temperature.
Use engine oil recommended by us.
Classification
API service classification CF class or higher
Viscosity SAE10W-30
Be sure to use CF class engine oil or superior class. (Using engine oil with poor quality may
shorten the life of the engine).
Follow the designated regulations to dispose of engine oil.
*Unit is delivered ex. factory, filled with engine oil recommended by engine manufacturer.
A100293E
Ambient temperature range and oil viscosity (SAE)