Cobramatic

®

Owner’s Manual - page 1

Section A

Installation

Technical Specifications

Wire Diameter Capacity ...................................... .030 - 1/16”
Wire Spool Capacity ........................................... 12” Standard
(Insulated or Non-Insulated)
Power Input ......................................................... 115 VAC 50/60 Hz,
.............................................................................150 Watts Peak (1.3 amps)
Weight .................................................................. 41 pounds
Shipping Weight ................................................. 46 pounds

Support Equipment Required

C.V. or C.C. Power Source of Sufficient Capacity for Your Needs.
Regulated Gas Supply and Hoses.
Properly Sized Power Leads from Power Source to Wire Feeder and Ground.

Coolant Recommendations for Liquid Cooled Guns

Use Cobra Coolant (Aluminum Protection), P/N 931-0060. Cobra Coolant

does not contain reactive sulphur or chlorine and does not react with copper,

brass or aluminum.
The coolant flow rate should be a minimum of 15 GPH (1 qt/min) between 35

and 45psi. Contact the re-circulator manufacturer for specifications on pres-

sure.

Machine Grounding

The Cobramatic

®

is grounded with the power source through the input power

cable. The power source grounding terminal must be properly connected to

electrical ground per the power source operating manual.

Mounting Location

The cabinet should be placed in a location where it can be protected from

damage. Lead lengths and accessibility must also be considered when

installing the cabinet.

Input Connections

(See Cabinet and Gun Hook-Up in the Appendix)

115 VAC
Your Wire Feeder comes factory ready with a standard 3-prong plug ready to

connect into any standard 115 VAC, 15 A receptacle. Several optional, pre-

wired harnesses are available for different power supplies and may be fac-

tory installed for a nominal installation fee. See part numbers and description

of each in the OPTIONAL KITS section of this manual.
The

115 VAC input power is connected to the PC Board on terminal strip J5

#1 (neutral-white) and J5 #2 (hot-black) and Ground (green) to the Cabinet

chassis. See diagram in the appendix.

Shielding Gas

In accordance with the required support equipment, the customer must pro-

vide a cylinder of shielding gas, a pressure regulator, a flow control valve,

and a hose from the flow control valve to the left bottom-most fitting on the

power block.
The end of the hose must have a male connector to fit the female 5/8-18

brass fitting. Use a 11/16” wrench to tighten.