Microsens MS453522M User Manual
Page 76
![background image](https://www.manualsdir.com/files/798581/content/doc076.png)
MICROSENS 8 Port Gigabit Ethernet Switch
User’s Manual
71
Default SNMP function : Enable
Default community name for GET: public
Default community name for SET: private
Default community name for Trap: public
Default Set function : Enable
Default trap host IP address: 0.0.0.0
Default port number :162
Trap:
In the switch, there are 6 trap hosts supported. Each of them has its own community
name and IP address; is user-definable. To set up a trap host means to create a trap
manager by assigning an IP address to host the trap message. In other words, the trap
host is a network management unit with SNMP manager receiving the trap message
from the managed switch with SNMP agent issuing the trap message. 6 trap hosts can
prevent the important trap message from losing.
For each public trap, the switch supports the trap event Cold Start, Warm Start, Link
Down, Link Up and Authentication Failure Trap. They can be enabled or disabled
individually. When enabled, the corresponded trap will actively send a trap message
to the trap host when a trap happens. If all public traps are disabled, no public trap
message will be sent. As to the Enterprise (no. 6) trap is classified as private trap,
which are listed in the Trap Alarm Configuration function folder.
Default for all public traps: Enable.
Fig. 3-24 Community and trap host setting