Microsens MS453522M User Manual
Page 181

MICROSENS 8 Port Gigabit Ethernet Switch
User’s Manual
176
set timer
Syntax:
set timer
Description:
To set gvrp join time, leave time, and leaveall time for each port.
Argument:
Leave Time must equal double Join Time at least.
Possible value:
Example:
MICROSENS(gvrp)# set timer 2-8 25 80 2000
show config
Syntax:
show config
Description:
To display the gvrp configuration.
Argument:
None.
Possible value:
None.
Example:
MICROSENS(gvrp)# show config
GVRP state: Enable
Port
Join Time
Leave Time
LeaveAll Time Applicant
Registrar Restricted
-------------------------------------------------------------------------------------------------------------------------------------
1
20
60
1000
Normal
Normal
Disable
2
25
80
2000
Normal
Normal
Disable
3
25
80
2000
Normal
Normal
Disable
4
25
80
2000
Normal
Normal
Disable
5
25
80
2000
Normal
Normal
Disable
6
25
80
2000
Normal
Normal
Disable
7
25
80
2000
Normal
Normal
Disable
8
25
80
2000
Normal
Normal
Disable