17

Troubleshooting

 Verify that you are using the right power cord/adapter (DC 12-48V),

please don’t use the power adapter with DC output bigger than 48V, or it

will burn this converter down.

 Select the proper UTP/STP cable to construct your network. Please check

that you are using the right cable. Use unshielded twisted-pair (UTP) or

shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3,

4 or 5 cables for 10Mbps connections or 100Ω Category 5 cable for

100Mbps connections. Also be sure that the length of any twisted-pair

connection does not exceed 100 meters (328 feet).

Diagnosing LED Indicators: the unit can be easily monitored through

panel indicators to assist in identifying problems, which describes

common problems you may encounter and where you can find possible

solutions.

 IF the power indicator does not light on when the power cord is plugged in,

you may have a problem with power cord. Than check for loose power

connections, power losses or surges at power outlet. IF you still cannot

resolve the problem, contact your local dealer for assistance.

 If the LED indicators are normal and the connected cables are correct and

the packets still cannot transmit. Please check your system’s Ethernet

devices’ configuration or status.