Dip-switch – Microsens MS655060-562 User Manual
Page 12

8
Off
Half-duplex mode
LNK/ACT
(fiber port)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
100M (RJ-45)
Yellow
On
Link to 100Mbps network
Off
Link to 10Mbps network
LNK/ACT
(RJ-45)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
DIP-Switch
The DIP-Switch is used to configure operation mode for LFP (Link Fault
Pass-Through) and operation mode for UTP/Fiber port. The default
value of DIP-switch is OFF.
S/W No
Status
Description
1
ON
Enables Port/Power Alarm
OFF
Disable Port/Power Alarm
2
ON
Enables LFP
OFF
Disables LFP
3
ON
100Base-FX Half-mode
OFF
100Base-FX Full-mode
4
ON
Media mode (100TX to 100FX)
OFF
Switching mode
Link Fault Pass-Through (DIP-Switch 2): When LFP enabled, it
allows UTP link failures to be reported to the fiber side and also allows
Fiber link failures to be reported to the UTP side. Therefore, a link fault
pass-through feature is provided in both UTP and Fiber side.
Media mode (DIP-Switch 4): When media mode is enabled (ON), it
operates with the minimum latency. The transmission flow does not wait
until entire frame is ready, but instead it forwards the received data
immediately after the data being received. And TP port should be forced
at 100M in this application. When DIP-Switch is in switching mode
(OFF), the converter function is the same as a Switch Hub.