beautypg.com

Fiber standards, Table 15, Iber – Microsens MS453490M Installation User Manual

Page 55: Tandards, 1000base-t

background image

A

PPENDIX

B

| Cables

Fiber Standards

– 55 –

A

DJUSTING

E

XISTING

C

ATEGORY

5 C

ABLING

TO

R

UN

1000BASE-T

If your existing Category 5 installation does not meet one of the test parameters
for 1000BASE-T, there are basically three measures that can be applied to try
and correct the problem:

1.

Replace any Category 5 patch cables with high-performance Category 5e or
Category 6 cables.

2.

Reduce the number of connectors used in the link.

3.

Reconnect some of the connectors in the link.

F

IBER

S

TANDARDS

The International Telecommunication Union (ITU-T) has standardized various
fiber types for data networks. These are summarized in the following table.

Table 15: Fiber Standards

ITU-T

Standard

Description

Application

G.651

Multimode Fiber

50/125-micron core

Short-reach connections in the 1300-

nm or 850-nm band

G.652

Non-Dispersion-Shifted Fiber

Single-mode, 9/125-micron core

Longer spans and extended reach.

Optimized for operation in the 1310-

nm band. but can also be used in the

1550-nm band

G.652.C

Low Water Peak Non-

Dispersion-Shifted Fiber

Single-mode, 9/125-micron core

Longer spans and extended reach.

Optimized for wavelength-division

multiplexing (WDM) transmission

across wavelengths from 1285 to

1625 nm. The zero dispersion

wavelength is in the 1310-nm region.

G.653

Dispersion-Shifted Fiber

Single-mode, 9/125-micron core

Longer spans and extended reach.

Optimized for operation in the region

from 1500 to 1600-nm.