Installing the switch, Selecting a site, Nstalling – Microsens MS453490M Installation User Manual

Page 33: Witch

background image

– 33 –

3

I

NSTALLING

THE

S

WITCH

S

ELECTING

A

S

ITE

Switch units can be mounted in a standard 19-inch equipment rack or on a flat
surface. Be sure to follow the guidelines below when choosing a location.

The site should:

be at the center of all the devices you want to link and near a power
outlet.

be able to maintain its temperature within 0 to 45 °C (32 to 113 °F)
and its humidity within 10% to 90%, non-condensing

provide adequate space (approximately two inches) on all sides for
proper air flow

be accessible for installing, cabling and maintaining the devices

allow the status LEDs to be clearly visible

Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.

Make sure that the unit is connected to a separate grounded power outlet
that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each
device and is powered from an independent circuit breaker. As with any
equipment, using a filter or surge suppressor is recommended.