beautypg.com

Realtime clock, Time_syn output – Meinberg PZF511 User Manual

Page 23

background image

23

DCF-time including announcement of changes in daylight saving and announcement of
leap seconds, changing the timezone in the setup menu has no effect on the generation.
The coding sheme is given below:

0

10

20

30

40

50

R

M

1

4

2

1
20

10

8

4

2

1

P

2

2

0

1

0

8

4

2

1

2

4

8

10

1

2

4

8

10

2

0

4

0

8

0

P

3

A1

Z1

Z2

A2

S

1

2

4

8

1

0

2

0

4

0

P

1

Kodierung

nach Bedarf

Minute

Stunde

Kalendertag

Wochentag

Kalender-

monat

Kalenderjahr

M

Minutenmarke (0.1 s)

R

Aussendung über Reserveantenne

A1

Ankündigung Beginn/Ende der Sommerzeit

Z1, Z2

Zonenzeitbits

Z1, Z2 = 0, 1:

Standardzeit (MEZ)

Z1, Z2 = 1, 0:

Sommerzeit (MESZ)

A2

Ankündigung einer Schaltsekunde

S

Startbit der codierten Zeitinformation

P1, P2, P3

gerade Paritätsbits

Time marks start at the beginning of new second. If a binary "0" is to be transmitted, the
length of the corresponding time mark is 100 msec, if a binary "1" is transmitted, the time
mark has a length of 200 msec. The information on the current date and time as well as
some parity and status bits can be decoded from the time marks of the 15th up to the 58th
second every minute. The absence of any time mark at the 59th second of a minute
signals that a new minute will begin with the next time mark. The DCF emulation output
is enabled immediately after power-up.

Realtime clock

The PZF511 includes a battery-backed realtime clock which runs crystal-precise in case
of power failure. A relativ accurate time is present immediately after power-up this way.
An additional RAM of the realtime clock is used to store important system parameters.

TIME_SYN output

This output is set to TTL-high if the receiver is in synchronous state (LED 'Freil'
switched off). The output level changes to TTL-low if the receiver is in asynchronous
state for more than one hour. The TIME_SYN output is available at the VG-connector
and can be used to release an alarm, for example.