Menu IRIG
This menu allows to select an IRIG, AFNOR or IEEE1344 timecode to be generated.
Besides the amplitude modulated sine wave signal, the PZF511 also provides an
unmodulated DC-Level Shift TTL output in parallel. Thus six time codes are available.
a) B002:
100pps, PWM DC signal, no carrier
BCD time-of-year
b) B122:
100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time-of-year
c) B003:
100pps, PWM DC signal, no carrier
BCD time-of-year, SBS time-of-day
d) B123:
100pps, AM sine wave signal, 1 kHz carrier frequency
BCD time-of-year, SBS time-of-day
e) AFNOR:
Code according to NFS-87500, 100pps,
AM-Sine wave signal, 1kHz carrier frequency,
BCD time-of-year, complete date, SBS time-of-day,
Signal level according to NFS-87500
f)
IEEE1344:
Code according to IEEE1344-1995, 100pps,
AM sine wave signal, 1kHz carrier frequency,
BCD time-of-year, SBS time-of-day, IEEE1344
extensions for date, timezone, daylight-saving
and leap second in control functions (CF) segment.
also see table 'Assignment of CF segment in IEEE1344 mode'
Menu IRIG REF
This menu lets the user select a timezone for the timecode generation.