Menu PAR.COMx

The three menus PAR.COM0 to PAR.COM2 allow the configuration of the serial
RS232 ports COM0 to COM2.

The following settings are possible:

Baudrate:

600, 1200, 2400, 4800, 9600 and 19200 Baud

Framing:

7N2, 7E1, 7E2, 8N1, 8N2, 8E1, 7O2 and 8O1

Menu SER.MODE

The three serial ports COM0 to COM2 are able to send a time string in three different
output modes. After the Set button is pressed the following is displayed:

The three letters on the right side represent the output mode of the serial ports COM0,

COM1 and COM2 (from the left to the right). With another brief push of the Set button
the first letter starts to blink and can be set to one of the following values now:

'S'

timestring starts with a new second

'M'

timestring starts with a new minute

'R'

timestring starts just after sending an ASCII '?' (3F hex) to the clock

Menu STR.COMx

The three menus STR.COM0 to STR.COM2 allow the selection of the serial time strings
for COM0, COM1 and COM2.

The following time strings can be selected:

- MBG - Meinberg Standard String
- Uni Erlangen String
- ATIS String