beautypg.com

Active low ibusy s2, Active low iend, Active high iend (default) – Measurement Computing Digital HS User Manual

Page 14

background image

2.2.2.2.4 S2-4 iBUSY POL: Input Port Busy Handshake Line

The input port busy handshake line, iBusy, is an input line sourced by the
Digital488HS/32. It can be configured as active high or active low. Factory default is
active high.

S2

iBUSY POL

OPEN

8

7

6

5

4

3

2

1

Active Low iBusy

S2

iBUSY POL

OPEN

8

7

6

5

4

3

2

1

Active High iBusy

(default)

Polarity Selection for the iBusy Handshake Line

2.2.2.2.5 S2-5 iEND POL: Input End Control Line Polarity

The iEND control line is latched into the ninth bit of the second byte input port. This
latched iEND signal directly drives the IEEE 488 EOI line during the second byte
transfer and can be used to signal the end of the transfer to the IEEE 488 controller.
iEND can be set for active high or active low operation. Default is active high.

OPEN

S2

iEND POL

8

7

6

5

4

3

2

1

Active Low iEND

OPEN

S2

iEND POL

8

7

6

5

4

3

2

1

Active High iEND

(default)