Chapter 5
Specifications
Typical for 25 °C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Analog input
A/D converter
Successive approximation type, min 200 kS/s conversion rate.
Resolution
16 bits, 1-in-65536
Number of channels
16 single-ended / 8 differential, software selectable
Input ranges
±10 V, ±5 V, ±500 mV, ±50 mV, software selectable
A/D pacing
Internal counter – ASIC. Software selectable time base:
Internal 40 MHz, 50 ppm stability
External source via AUXIN<5:0>, software selectable.
External convert strobe: A/D CONVERT
Software paced
Burst mode
Software selectable option, burst rate = 5 µs.
A/D gate sources
External digital: A/D GATE
A/D gating modes
External digital: Programmable, active high or active low, level or edge
A/D trigger sources
External digital: A/D START TRIGGER
A/D STOP TRIGGER
A/D triggering modes
External digital: Software-configurable for rising or falling edge.
Pre-/post-trigger: Unlimited number of pre-trigger samples, 16 Meg post-trigger samples.
ADC pacer out
Available at user connector: A/D PACER OUT
RAM buffer size
8 K samples
Data transfer
DMA
Programmed I/O
DMA modes
Demand or non-demand using scatter gather.
Configuration memory
(see Note 1)
Up to 8 K elements in the queue. Programmable channel, gain, and offset.
Streaming-to-disk rate
200 kS/s, system dependent
Note 1:
Mixing high gains (±500 mV, ±50 mV) with low gains (±10 V, ±5 V) within the channel-gain
queue is not supported.
Accuracy
200 kS/s sampling rate, single channel operation and a 15-minute warm-up. Accuracies listed are for
measurements made following an internal calibration. They are valid for operational temperatures within ±1 °C
of internal calibration temperature and ±10 °C of factory calibration temperature. Calibrator test source high
side tied to channel 0 high and low side tied to channel 0 low. Low-level ground is tied to channel 0 low at the
user connector.
Table 1. Absolute accuracy specifications
Range
Absolute Accuracy
±10 V
±29.4 LSB
±5 V
±13.1 LSB
±500 mV
±30.9 LSB
±50 mV
±45.2 LSB