beautypg.com

Configuring the hardware, Differential input mode, Single-ended input mode – Measurement Computing PCI-DAS1002 User Manual

Page 13: Connecting the board for i/o operations, Connectors, cables – main i/o connector

background image

PCI-DAS1002 User's Manual

Installing the PCI-DAS1002

13

Configuring the hardware

All hardware configuration options on the PCI-DAS1002 are software controlled. You can select some of the
configuration options using InstaCal, such as the analog input configuration (16 single-ended or eight
differential channels), and the source for the two independent counters. Once selected, any program that uses
the Universal Library will initialize the hardware according to these selections.

For general information regarding analog signal connection and configuration, refer to the Guide to Signal
Connections
(available on our web site at

www.mccdaq.com/signals/signals.pdf

).

Differential input mode

When all channels are configured for differential input mode, eight analog input channels are available. In this
mode, the input signal is measured with respect to the low input. The input signal is delivered through three
wires:

 The wire carrying the signal to be measured connects to CH# IN HI.
 The wire carrying the reference signal connects to CH# IN LO.
 The third wire, typically a system ground, connects to LLGND.

Single-ended input mode

When all channels are configured for single-ended input mode, 16 analog input channels are available. In this
mode, the input signal is referenced to the board's signal ground (LLGND). The input signal is delivered
through two wires:

 The wire carrying the signal to be measured connects to CH# IN HI.
 The second wire connects to LLGND.

Connecting the board for I/O operations

Connectors, cables

– main I/O connector

The table below lists the board connectors, applicable cables, and compatible accessory boards for the PCI-
DAS1002.

Board connectors, cables, accessory equipment

Connector type

100 pin high density Robinson Nugent connector

Compatible cables

C100FF-x, unshielded ribbon cable. x = length in feet (Figure 2 on on page 16)

Compatible accessory products

(with the C100FF-x cable)

ISO-RACK16/P

ISO-DA02/P

CIO-ERB08*

CIO-ERB24*

SSR-RACK08*

SSR-RACK24*

BNC-16SE

BNC-16DI

CIO-MINI50 (2 required)

CIO-TERM100 (1 required)

SCB-50 (1 required)

* These devices require the DADP-5037 PCI-DAS to 37-pin SSR and ERB adapter board.