Unpacking the pci-das08, Installing the software, Installing the pci-das08 – Measurement Computing PCI-DAS08 User Manual
Page 10: Unpacking the pci-das08 -2, Installing the software -2, Installing the pci-das08 -2

PCI-DAS08 User's Guide
Installing the PCI-DAS08
!
Signal termination and conditioning accessories
MCC provides signal termination products for use with the PCI-DAS08. Refer to the "
termination and signal conditioning
" section for a complete list of compatible accessory products.
Unpacking the PCI-DAS08
As with any electronic device, you should take care while handling to avoid damage from static
electricity. Before removing the PCI-DAS08 from its packaging, ground yourself using a wrist strap or by
simply touching the computer chassis or other grounded object to eliminate any stored static charge.
If any components are missing or damaged, notify Measurement Computing Corporation immediately by
phone, fax, or e-mail:
!
Phone: 508-946-5100 and follow the instructions for reaching Tech Support.
!
Fax: 508-946-9500 to the attention of Tech Support
!
Email:
!
Installing the software
Refer to the Quick Start Guide for instructions on installing the software on the Measurement Computing Data
Acquisition Software CD. This booklet is available in PDF at
.
Installing the PCI-DAS08
The PCI-DAS08 board is completely plug-and-play. There are no switches or jumpers to set. To install your
board, follow the steps below.
Install the MCC DAQ software before you install your board
The driver needed to run your board is installed with the MCC DAQ software. Therefore, you need to install
the MCC DAQ software before you install your board. Refer to the Quick Start Guide for instructions on
installing the software.
1.
2.
3.
Turn your computer off, remove the cover, and insert your board into an available PCI slot.
Close your computer and turn it on.
If you are using an operating system with support for plug-and-play (such as Windows 2000 or
Windows XP), a dialog box pops up as the system loads indicating that new hardware has been detected. If
the information file for this board is not already loaded onto your PC, you will be prompted for the disk
containing this file. The MCC DAQ software contains this file. If required, insert the Measurement
Computing Data Acquisition Software CD and click
OK
.
To test your installation and configure your board, run the InstaCal utility installed in the previous section.
Refer to the Quick Start Guide that came with your board for information on how to initially set up and
load InstaCal.
If your board has been powered-off for more than 10 minutes, allow your computer to warm up for at least
15 minutes before acquiring data. This warm-up period is required for the board to achieve its rated accuracy.
The high speed components used on the board generate heat, and it takes this amount of time for a board to
reach steady state if it has been powered off for a significant amount of time.
2-2