3.7 SIGNAL CONNECTION

The analog outputs of the CIO-DAC16/16 and the DAC08/16 are two-wire hook-ups;
a signal, labeled D/A # OUT on the connector diagram after this section, and a Low
Level Ground (LLGND). The low level ground is an analog ground and is the ground
reference which should be used for all analog hook-ups.

Possible analog output ranges are:

Bipolar Ranges

±10V

±5V

and
Unipolar Ranges 0 to 10V

0 to 5V

Each of the DAC outputs are individually buffered through an OP-27 operational
amplifier (OP-AMP). The OP-27s are socketted so that if one goes bad it can be
replaced in the field. The OP-27 for each channel is located just below the calibration
potentiometers for that channel.

Each channel is capable of sinking or sourcing ±5 mA. That means a load of 2K
Ohms can be connected to each channel at the full rated output swing of +10V.

As the load resistance is raised from 2K up to 10 Meg

or more, the output load on

the DAC decreases. Any resistance greater than 2K is acceptable.

As the load resistance decreases, the output load increases. The OP-27 responds by
producing a lower output voltage. If your DAC board will not produce the output
voltage specified by the code & range combination, check the load with an ohmmeter.

Under normal circumstances you will not damage the OP-27 by connecting the output
to ground. If your connection results in a failure of the OP-27, chances are good that
there was some potential at the connecting point in addition to a load at ground or
between 0 and 2K ohms. Explore the point with a DVM before reconnecting the
CIO-DAC16/16 or DAC08/16 (and after replacing the OP-27 of course). Connect the
negative lead of the DVM to any LLGND pin of the CIO-DAC16/16 or DAC08/16.