Setting the batch count – MBM Corporation 352S User Manual
Page 60

Operator's Manual
multipli 35
Counters
Mathias Bäuerle GmbH
65
Setting the Batch Count
For batch counting, two settings are needed:
•
the desired number of sheets per batch (preselection)
•
the length of the gap between sheets (interval)
Setting only one value will not enable batch counting.
The function of the batch counter can be switched on or off by pressing key
Key:
Explanation:
Switching on the
Batch Counter
The green LED indicates that the Batch Count setting feature is active.
The segment and the analog display come on.
Setting the Desired
Number of Sheets
(one-up)
Key:
Explanation:
Press the key several times until the correct number
of sheets is shown in the display.
When working with a kicker, the smallest settable batch count is 10!
Setting the Interval
Time (Length of
Sheet Gap)
Key:
Explanation:
Press the key several times - the number of
flashing LEDs in the analog display corresponds
to a certain sheet gap.
Short interval:
Only a few LEDs are on.
Long interval:
Most LEDs are on.
When working with a kicker, the setting depends on the type of paper.
Thin paper:
Only a few LEDs are flashing
Thick paper:
Most LEDs are flashing
The interval can be changed with the machine running.