Installation
506066
20
Location Requirements
Select a location with a solid floor. Dryers installed in
residential garages must be elevated 46 cm (18 inches)
above the floor.
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer
with a 1/4 inch driver. All four legs must rest firmly on
the floor so the weight of the dryer is evenly
distributed. The dryer must not rock.
The dryer needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown in Figure 13.)
Figure 13
** NOTE: For new installations, locate top of wall vent 106.7 cm (42 inches) above floor to make venting easier to
connect.
D317I
1
Closet Door
3
Outer Wall of Enclosure
2
Centered Air Openings
(Two openings minimum)
B
A
C
D
A
E
3
FRONT VIEW
(w/o Closet Door)
Area
Description
Free Standing/Alcove
Installation
Closet Installation
A
Dryer sides and rear clearance
0 cm (0 in.)
0 cm (0 in.)
B
Dryer top clearance
30.5 cm (12 in.)
30.5 cm (12 in.)
C
Dryer front clearance
Not Applicable
5.1 cm (2 in.)
D
Exhaust duct clearance to combustible
material
5.1 cm (2 in.)
5.1 cm (2 in.)
E
Weather hood to ground clearance
30.5 cm (12 in.)
30.5 cm (12 in.)
F
Distance from floor or ceiling to hole
edge
Not Applicable
7.6 cm (3 in.)
SIDE VIEW
A
FRONT VIEW
(Closet Door)
**106.7 cm
(42 in.)
F
F
1
2 (G)