Step 3: (gas dryer only) connect gas supply pipe – Kleenmaid LEK37A Version 506066R4 User Manual
Page 12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
506066
10
Step 3: (Gas Dryer ONLY) Connect Gas
Supply Pipe
For further assistance, refer to section on Gas
Requirements.
1. Make certain your dryer is equipped for use with
the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a
3/8 inch NPT gas connection.
2. Remove the shipping cap from the gas
connection at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.
3. Connect to gas supply pipe.
4. Tighten all connections securely. Turn on gas and
check all pipe connections (internal and external)
for gas leaks with a non-corrosive leak detection
fluid.
5. For L.P. (Liquefied Petroleum) gas connection,
refer to section on Gas Requirements.
Figure 5
D246I
1
New Stainless Steel Flexible Connector –
Use only if allowed by local codes
(Use design AGA certified connector)
3
Shut-Off Valve
4
3/8 in. NPT Gas Connection
2
Pressure Test Point
1
2
3
4