Gas dryers, Warning – Kleenmaid LEK37A Version 506066R4 User Manual
Page 18
![background image](https://www.manualsdir.com/files/793113/content/doc018.png)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
506066
16
Gas Dryers
NOTE: The wiring diagram is located inside the
control hood.
IMPORTANT: The electrical installation in the site
shall comply with the latest edition of Australian
Electrical Standards, AS3000, SAA wiring rules,
and such local regulations that might apply.
This dryer is designed to be operated on a two wire,
plus earth, 240 Volt, 50 Hertz, single-phase circuit,
fused at 10 amperes.
Insert the dryer’s lead-in cord plug into an earthing
three-slot wall receptacle on a separate circuit. DO
NOT OPERATE OTHER APPLIANCES ON THE
SAME CIRCUIT WHEN THE DRYER IS
OPERATING. DO NOT USE AN EXTENSION
CORD.
If the supply cord is damaged, it must be replaced by a
special cord or assembly available from the
manufacturer or its service agent.
Figure 11
If this appliance is supplied from a cord
extension set or an electrical portable outlet
device, the cord extension set or electrical
portable outlet device must be positioned
so that it is not subject to splashing or
ingress of moisture.
W563
WARNING
D676I
1
Lead-In Cord
2
Earth Screw
3
Lead-In Cord Plug
4
Earth
10A
250 V
D676I
1
2
3
4