beautypg.com

Normal operating noises for the appliance – Kleenmaid ICK98X User Manual

Page 30

background image

30

Visual
indication

Measure

Fault

F4

The cooking hob is too hot
and has turned off.

Check whether there is any hot cookware on the control
panel. Remove the cookware from the control panel. Wait
a few minutes until the control panel has cooled a little. If
after connection F4 appears again, call the technical
assistance service.

F8

The cooking zone has
been working at a high
power and continuously
for too long.

Automatic time limitation has been activated.
To continue cooking touch any sensor.

ç1

The power voltage is too
low.

Deactivate the hob. Wait a few seconds before connecting
it again.
If the indication continues, contact your electricity
supplier.

ç2/ç3

The cooking zone has
overheated.

It has been automatically deactivated to protect your hob.
Wait a few minutes for it to cool down and switch it back
on again.

U400

The cooking hob is not
well connected.

Disconnect the cooking hob from the mains. Check the
connection and connect it again correctly.
If the indication continues, notify the technical assistance
service.

Induction heating technology is based on the vibration
resistance of certain metals when subjected to
highĆfrequency waves. In some circumstances, these
vibrations can cause a certain degree of noise, such
as the following:

This occurs when cooking at a high power. The cause
of this is the amount of energy which is transmitted
from the hob to the cookware. This noise disappears
or becomes quieter when the power is turned down.

This occurs when the cookware is empty. This noise
disappears when water or food is added to
the cookware.

Normal operating
noises for the
appliance

Low humming like a
transformer

Quiet whistling